w w w . a c t i . c o m
* All specifications are subject to change without notice.
* All brand names and registered trademarks are the property of their respective owners.
72
ACD-2300
Vi de o S e r ver
PRODUCT SPECIFICATION
ORDERING INFORMATION
Model Name Description
ACD-2300 1U Rackmount 8-channel Video Server with Two Way Audio
External I/O
Reset Button Factory default
LED System Status (per channel)
Network
Ethernet Port Ethernet(10/100 Base-T), RJ-45 connector
Protocol
TCP, UDP, IP, HTTP, DHCP, PPPoE, RTP,
RTSP,FTP,SMTP,DNS,DDNS,NTP,ICMP,I
GMP,ARP,3GPP
Software
Web Browser Microsoft Internet Explorer 6.0 or above
SDK ACTi SDK-10000
PTZ Protocol*
Pelco-p_type1, Pelco-P_type2, Pelco-D,
Dynacolor, Samsung, VCL, Videotrek,
Kampro-V1,Kampro-V2
Security
Password Protection: Configured by the
Administrator
Operating
Temperature 0 ºC ~ 50 ºC (32 ºF ~ 122 ºF)
Power
Power Requirement AC 100 ~ 240 V 50/60 Hz
Power Consumption 50 W
Physical
Dimensions (WxHxD)
444 mm x 44.5 mm x 272 mm
(17.48” x 1.75” x 10.72”)
Weight 3.9 Kg
* These PTZ protocols are supported in ACTi NVR and Streaming Explorer.
** Adjust by inside jumper.
Video Compression
Compression MPEG-4 SP, MJPEG selectable
Picture Resolution
Full D1 (720x480 in NTSC, 720x576 in PAL)
VGA (640x480 in NTSC, 640x480 in PAL)
CIF (352x240 in NTSC, 352x288 in PAL)
QCIF (176x120 in NTSC, 176x144 in PAL)
(per channel)
Bit Rate 28 K ~ 3 M bps (per channel)
Image Frame Rate
30fps at full D1 resolution (NTSC)
25fps at full D1 resolution (PAL)
Multi-stream
Up to 2 configurable frame rate/bit rate
streams for preview and recording
(per channel)
Video Input
Composite Input
8, CVBS, 1.0Vp-p with 75Ω loading, BNC
connector
Video Output
Composite Output N/A
Audio Input
Compression 8kHz, Mono, PCM
Audio Line Input
8, Unbalanced, 1.4Vp-p, 1Vrms, terminal
block
Audio Output
Compression 8kHz, Mono, PCM
Audio Line Output
8, Unbalanced, 1.4Vp-p, 1Vrms, terminal
block
Alarm
Input 2, TTL, terminal block (per channel)
Output 2, TTL, terminal block (per channel)
Remote Control
Serial Port
RS-485: Half Duplex, terminal block
RS-422: Full Duplex, terminal block
RS-232**: Full Duplex, terminal block
(per channel)
Comentarios a estos manuales