2Notes on SafetyID 442281.00WE KEEP THINGS MOVINGOperating Manual102.4 Ambient conditionsInverters are products of the restricted sales class as descr

Pagina 3

DiagnosisOperating Manual100ID 442281.00WE KEEP THINGS MOVING1313.3.31 75:Ax4braketestResolution Level Response Fault counterFor active brake manage-m

Pagina 4

DiagnosisOperating Manual101ID 442281.00WE KEEP THINGS MOVING1313.3.32 #004:illeg.Instr13.3.33 #006:illSlotInstResolution Level ResponseAn unknown ope

Pagina 5

DiagnosisOperating Manual102ID 442281.00WE KEEP THINGS MOVING1313.3.34 #009:CPU AddrErr13.3.35 #00c:StackOverflResolution Level ResponseThe address fo

Pagina 6 - 1Introduction

DiagnosisOperating Manual103ID 442281.00WE KEEP THINGS MOVING1313.3.36 *ParaModul ERROR:update firmware!13.3.37 *ParaModul ERROR: file not foundResolu

Pagina 7

DiagnosisOperating Manual104ID 442281.00WE KEEP THINGS MOVING1313.3.38 *ParaModul ERROR: Checksum error13.3.39 *ParaModul ERROR: ksb write errorResolu

Pagina 8

DiagnosisOperating Manual105ID 442281.00WE KEEP THINGS MOVING1313.3.40 *ConfigStartERROR parameters lost13.3.41 *ConfigStartERROR remanents lostResolu

Pagina 9 - 2 Notes on Safety

DiagnosisOperating Manual106ID 442281.00WE KEEP THINGS MOVING1313.3.42 *ConfigStartERROR unknown block13.3.43 *ConfigStartERROR unknown stringResoluti

Pagina 10 - WE KEEP THINGS MOVING

DiagnosisOperating Manual107ID 442281.00WE KEEP THINGS MOVING1313.3.44 *ConfigStartERROR unknown scale13.3.45 *ConfigStartERROR unknown limitResolutio

Pagina 11

DiagnosisOperating Manual108ID 442281.00WE KEEP THINGS MOVING1313.3.46 *ConfigStartERROR unknown post-wr13.3.47 *ConfigStartERROR unknown pre-rdResolu

Pagina 12

DiagnosisOperating Manual109ID 442281.00WE KEEP THINGS MOVING1313.3.48 *ConfigStartERROR unknown hiding13.3.49 no configuration paramodul errorWhen di

Pagina 13

Notes on SafetyOperating ManualID 442281.00WE KEEP THINGS MOVING1122.5 Qualified personnelSince the devices may harbor residual risks, all configurati

Pagina 14

NotesID 442281.00WE KEEP THINGS MOVING110

Pagina 15 - 3 Commissioning an inverter

Global PresenceAddress registersAlways up to date on the internet: www.stoeber.de → contact• Technical Offices (TB) for advice and marketing in German

Pagina 16

mSTÖBER ANTRIEBSTECHNIK GmbH + Co. KGKieselbronner Str. 1275177 PFORZHEIMGERMANYTel. +49 (0)7231 582-0Fax. +49 (7231) 582-1000E-Mail: [email protected]

Pagina 17

2Notes on SafetyID 442281.00WE KEEP THINGS MOVINGOperating Manual122.7 Installation and connectionInstallation and connection work are only permitted

Pagina 18

Notes on SafetyOperating ManualID 442281.00WE KEEP THINGS MOVING132You can then start your work on the drive controller. Repairs may only be per-forme

Pagina 19

2Notes on SafetyID 442281.00WE KEEP THINGS MOVINGOperating Manual142.11 Presentation of notes on safetyNOTICENoticemeans that property damage may occu

Pagina 20

Commissioning an inverterOperating ManualID 442281.00WE KEEP THINGS MOVING1533 Commissioning an inverterFor the solution of a technical drive task, th

Pagina 21

3Commissioning an inverterID 442281.00WE KEEP THINGS MOVINGOperating Manual165 Switch on the enable.Ö The inverter is in the 4:Enabled device state.Ö

Pagina 22

Commissioning an inverterOperating ManualID 442281.00WE KEEP THINGS MOVING173The following eight states exist in the standard device state machine in

Pagina 23 - 4 Parameterize

3Commissioning an inverterID 442281.00WE KEEP THINGS MOVINGOperating Manual18The following Figure 3 1 shows which state changes are possible. The tabl

Pagina 24 - 1.E250.2

Commissioning an inverterOperating ManualID 442281.00WE KEEP THINGS MOVING1937 Operation enabled Æ Quick stop active • Quick stop signal on high level

Pagina 25

Table of contentsID 442281.00Titel des DokumentsWE KEEP THINGS MOVING2Table of contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 26

3Commissioning an inverterID 442281.00WE KEEP THINGS MOVINGOperating Manual203.2 Device state machine acc. to DSP 402The device state machine as per D

Pagina 27 - 4.3 Operator panel

Commissioning an inverterOperating ManualID 442281.00WE KEEP THINGS MOVING213The difference between the standard device state machine is the possible

Pagina 28

3Commissioning an inverterID 442281.00WE KEEP THINGS MOVINGOperating Manual223 Ready for switchon Æ Switched on Enable on high level (E19 Bit 0 = 1) a

Pagina 29 - 5 Parameterizing motor data

ParameterizeOperating ManualID 442281.00WE KEEP THINGS MOVING2344 ParameterizeThe user interfaces of the 5th generation of STÖBER inverters consist of

Pagina 30

4ParameterizeID 442281.00WE KEEP THINGS MOVINGOperating Manual244.1 ParametersParameters perform various tasks in the inverter system:• Adjust the app

Pagina 31

ParameterizeOperating ManualID 442281.00WE KEEP THINGS MOVING254L.. PLCopen reference valuesOnly with positioning application PLCopenN.. Posi.switches

Pagina 32

4ParameterizeID 442281.00WE KEEP THINGS MOVINGOperating Manual264.1.2 Data types4.1.3 Parameter list structureTo address parameters via the fieldbus,

Pagina 33

ParameterizeOperating ManualID 442281.00WE KEEP THINGS MOVING2744.2 POSIToolThe POSITool software represents the many-sided interface between user and

Pagina 34 - 6 Parameterizing encoder data

4ParameterizeID 442281.00WE KEEP THINGS MOVINGOperating Manual28The parameter menu of the inverter is divided into menu groups. The menu groups are ar

Pagina 35

Parameterizing motor dataOperating ManualID 442281.00WE KEEP THINGS MOVING2955 Parameterizing motor dataSpecifications and control mode must be given

Pagina 36 - 7 Parameterizing brake data

Table of contentsID 442281.00Titel des DokumentsWE KEEP THINGS MOVING35 Parameterizing motor data. . . . . . . . . . . . . . . . . 295.1 Selection in

Pagina 37

5Parameterizing motor dataID 442281.00WE KEEP THINGS MOVINGOperating Manual30Fig. 5-1: Motor selection in Step 5 of the configuration assistant5.2 Dir

Pagina 38

Parameterizing motor dataOperating ManualID 442281.00WE KEEP THINGS MOVING315The following actions will make it easier for you to enter parameters• Yo

Pagina 39

5Parameterizing motor dataID 442281.00WE KEEP THINGS MOVINGOperating Manual325.3 Further motor datas5.3.1 Current controllerParameters B64 to B68 pert

Pagina 40 - Parameterizing brake resistor

Parameterizing motor dataOperating ManualID 442281.00WE KEEP THINGS MOVING3355.4 Parameterize motor temperature sensor evaluationYou can connect a max

Pagina 41 - 10 Parameterizing in-/outputs

6Parameterizing encoder dataID 442281.00WE KEEP THINGS MOVINGOperating Manual346 Parameterizing encoder dataThe following paragraphs explain the setti

Pagina 42

Parameterizing encoder dataOperating ManualID 442281.00WE KEEP THINGS MOVING3566.3 Interface X101 (BE encoder)You can connect the following encoders t

Pagina 43

7Parameterizing brake dataID 442281.00WE KEEP THINGS MOVINGOperating Manual367 Parameterizing brake dataMotors with holding brakes can be connected to

Pagina 44

Parameterizing brake dataOperating ManualID 442281.00WE KEEP THINGS MOVING377The current motor torque is stored in the setting F08 = 1:active while th

Pagina 45

7Parameterizing brake dataID 442281.00WE KEEP THINGS MOVINGOperating Manual38Depending on how you parameterize it on assistant page holding brake, bra

Pagina 46

Parameterizing axis managementOperating ManualID 442281.00WE KEEP THINGS MOVING3988 Parameterizing axis managementThis section describes axis manageme

Pagina 47

Table of contentsID 442281.00Titel des DokumentsWE KEEP THINGS MOVING413 Diagnosis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6013.1

Pagina 48 - 12 Service

9Parameterizing brake resistorID 442281.00WE KEEP THINGS MOVINGOperating Manual409 Parameterizing brake resistorTo remove excess braking energy from t

Pagina 49

Parameterizing in-/outputsOperating ManualID 442281.00WE KEEP THINGS MOVING411010 Parameterizing in-/outputsThis chapter discusses the linking of cont

Pagina 50

10Parameterizing in-/outputsID 442281.00WE KEEP THINGS MOVINGOperating Manual42All available parameters can be entered in the source pa-rameters.To be

Pagina 51

Communication between inverter and PCOperating ManualID 442281.00WE KEEP THINGS MOVING431111 Communication between inverter and PCCommunication betwee

Pagina 52

11Communication between inverter and PCID 442281.00WE KEEP THINGS MOVINGOperating Manual44used. In this case, you can use the global settings of POSIT

Pagina 53

Communication between inverter and PCOperating ManualID 442281.00WE KEEP THINGS MOVING4511First case: Different configurationsWhen POSITool determines

Pagina 54

11Communication between inverter and PCID 442281.00WE KEEP THINGS MOVINGOperating Manual46When online mode is concluded with a partial reverse documen

Pagina 55

Communication between inverter and PCOperating ManualID 442281.00WE KEEP THINGS MOVING4711If you want to check the differences between the parameters

Pagina 56

12ServiceID 442281.00WE KEEP THINGS MOVINGOperating Manual4812 ServiceThis chapter lists various service jobs and explains their performance.12.1 Repl

Pagina 57

ServiceOperating ManualID 442281.00WE KEEP THINGS MOVING491212.2 Replacing an applicationThis chapter provides you with a guide to the simple change o

Pagina 58

Table of contentsID 442281.00Titel des DokumentsWE KEEP THINGS MOVING513.3.25 69:Motor connect. . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Pagina 59

12ServiceID 442281.00WE KEEP THINGS MOVINGOperating Manual503 Remove the Paramodule from the inverter.4 Install the new Paramodule (Paramodule with ch

Pagina 60 - 13.1 LED

ServiceOperating ManualID 442281.00WE KEEP THINGS MOVING511212.3 Copying ParamoduleThe following section describes how to copy a Paramodule so that an

Pagina 61

12ServiceID 442281.00WE KEEP THINGS MOVINGOperating Manual5212.4 Replacing the firmwareThe following section describes how to replace the firmware of

Pagina 62

ServiceOperating ManualID 442281.00WE KEEP THINGS MOVING5312Replacing the firmware1 Start the program Download.exe.Ö The following dialog screen appea

Pagina 63

12ServiceID 442281.00WE KEEP THINGS MOVINGOperating Manual546 Press the OK button.Ö The following dialog screen appears:7 Select the mot file which is

Pagina 64

ServiceOperating ManualID 442281.00WE KEEP THINGS MOVING5512If the download failed, check the following points:1. After you pressed the button Downloa

Pagina 65

12ServiceID 442281.00WE KEEP THINGS MOVINGOperating Manual56A00 Save valuesWhen you activate A00.0, the inverter's current configuration and the

Pagina 66

ServiceOperating ManualID 442281.00WE KEEP THINGS MOVING571212.5.2 Actions with enableActions which require that the motors be energized before these

Pagina 67

12ServiceID 442281.00WE KEEP THINGS MOVINGOperating Manual58You can read the following results from the third element (B41.2):0: error free: The actio

Pagina 68

ServiceOperating ManualID 442281.00WE KEEP THINGS MOVING5912During activation, the enable must be inactive. If you have started the action in B43.0, y

Pagina 69

1IntroductionID 442281.00WE KEEP THINGS MOVINGOperating Manual61IntroductionAxis management is integrated on the inverters. This offers the following

Pagina 70

13DiagnosisID 442281.00WE KEEP THINGS MOVINGOperating Manual6013 Diagnosis13.1 LEDThe LEDs on the front of the inverter give you a quick overview of t

Pagina 71

DiagnosisOperating ManualID 442281.00WE KEEP THINGS MOVING611313.2 DisplayThe display gives the user a detailed response message on the state of the i

Pagina 72

13DiagnosisID 442281.00WE KEEP THINGS MOVINGOperating Manual62Error during active configurationEvents during active configuration are used to monitor

Pagina 73

DiagnosisOperating ManualID 442281.00WE KEEP THINGS MOVING6313...during device startupDuring device startup, configuration and parameters, flags and s

Pagina 74

DiagnosisOperating Manual64ID 442281.00WE KEEP THINGS MOVING1313.3 Events13.3.1 31:Short/ground.13.3.2 32:Short/gr.intResolution Level Response Fault

Pagina 75

DiagnosisOperating Manual65ID 442281.00WE KEEP THINGS MOVING1313.3.3 33:OvercurrentResolution Level Response Fault counterThe total motor current exce

Pagina 76

DiagnosisOperating Manual66ID 442281.00WE KEEP THINGS MOVING1313.3.4 34:Hardw.faultResolution Level Response Fault counterThere is a hardware fault. M

Pagina 77

DiagnosisOperating Manual67ID 442281.00WE KEEP THINGS MOVING1313.3.5 35:WatchdogResolution Level Response Fault counterThe watchdog of the microproces

Pagina 78

DiagnosisOperating Manual68ID 442281.00WE KEEP THINGS MOVING1313.3.6 36:High voltageResolution Level Response Fault counterThe voltage in the intermed

Pagina 79

DiagnosisOperating Manual69ID 442281.00WE KEEP THINGS MOVING1313.3.7 37:EncoderResolution Level Response Fault counterError due to encoderMalfunc-tion

Pagina 80

IntroductionOperating ManualID 442281.00WE KEEP THINGS MOVING711.2 ReadersUsers who are familiar with the control of drive systems and have a knowledg

Pagina 81

DiagnosisOperating Manual70ID 442281.00WE KEEP THINGS MOVING138:X4-EnDatCRC Errors accumulate during data transfer.• Check the connection and shieldin

Pagina 82

DiagnosisOperating Manual71ID 442281.00WE KEEP THINGS MOVING1317:X140-wire break A wire break was detected at X120.• Check the connected cable (encode

Pagina 83

DiagnosisOperating Manual72ID 442281.00WE KEEP THINGS MOVING1321:X4-Wire break A wire break from one or more tracks was detected.• Check the encoder c

Pagina 84

DiagnosisOperating Manual73ID 442281.00WE KEEP THINGS MOVING1329:AX5000/IncEnc A faulty POSISwitch AX 5000 op-tion at X4 or a wire break in the A-trac

Pagina 85

DiagnosisOperating Manual74ID 442281.00WE KEEP THINGS MOVING1313.3.8 38:TempDev.sens35:battery empty When switching on the inverter, it was determined

Pagina 86

DiagnosisOperating Manual75ID 442281.00WE KEEP THINGS MOVING1313.3.9 39:TempDev i2tResolution Level Response Fault counterThe i2t model for the invert

Pagina 87

DiagnosisOperating Manual76ID 442281.00WE KEEP THINGS MOVING1313.3.10 40:Invalid dataResolution Level Response Fault counterA data error was detected

Pagina 88

DiagnosisOperating Manual77ID 442281.00WE KEEP THINGS MOVING1332:el. mot-type no name plate data available • For STÖBER standard motor: Please contact

Pagina 89

DiagnosisOperating Manual78ID 442281.00WE KEEP THINGS MOVING1313.3.11 41:Temp.MotorTMSResolution Level Response Fault counterMotor temperature sensor

Pagina 90

DiagnosisOperating Manual79ID 442281.00WE KEEP THINGS MOVING1313.3.12 42:TempBrakeRes13.3.13 44:External faultResolution Level Response Fault counterT

Pagina 91

1IntroductionID 442281.00WE KEEP THINGS MOVINGOperating Manual8The accessories of the inverter are documented in the following manuals:1.4 Further sup

Pagina 92

DiagnosisOperating Manual80ID 442281.00WE KEEP THINGS MOVING1313.3.14 45:oTempMot. i2tResolution Level Response Fault counterThe i2t model for the mot

Pagina 93

DiagnosisOperating Manual81ID 442281.00WE KEEP THINGS MOVING1313.3.15 46:Low voltageResolution Level Response Fault counterA problem with the supply v

Pagina 94

DiagnosisOperating Manual82ID 442281.00WE KEEP THINGS MOVING1313.3.16 47:TorqueLimitResolution Level Response Fault counterThe maximum torque permitte

Pagina 95

DiagnosisOperating Manual83ID 442281.00WE KEEP THINGS MOVING1313.3.17 52:CommunicationResolution Level Response Fault counterCommunication malfunction

Pagina 96

DiagnosisOperating Manual84ID 442281.00WE KEEP THINGS MOVING134:PZD-Timeout • Failure of the cyclic data connec-tion (PROFIBUS master no lon-ger sends

Pagina 97

DiagnosisOperating Manual85ID 442281.00WE KEEP THINGS MOVING137:EtherCAT-DcSYN If the inverter is synchronised to Eth-erCAT by means of the Distribute

Pagina 98

DiagnosisOperating Manual86ID 442281.00WE KEEP THINGS MOVING1311:IGB Sync Erro The synchronisation within the in-verter is faulty as the configuration

Pagina 99

DiagnosisOperating Manual87ID 442281.00WE KEEP THINGS MOVING1313.3.18 55:OptionBoardResolution Level Response Fault counterError when operating with o

Pagina 100 - Diagnosis

DiagnosisOperating Manual88ID 442281.00WE KEEP THINGS MOVING139:ECS5000failure ECS 5000 was detected, installed and failed.• Uninstall and reinstall t

Pagina 101

DiagnosisOperating Manual89ID 442281.00WE KEEP THINGS MOVING1313.3.19 56:OverspeedResolution Level Response Fault counterThe measured speed is larger

Pagina 102

Notes on SafetyOperating ManualID 442281.00WE KEEP THINGS MOVING922 Notes on SafetyThe devices may cause risks. For these reasons, comply with the fol

Pagina 103

DiagnosisOperating Manual90ID 442281.00WE KEEP THINGS MOVING1313.3.20 57:Runtime usageResolution Level Response Fault counterThe cycle time of a real

Pagina 104

DiagnosisOperating Manual91ID 442281.00WE KEEP THINGS MOVING1313.3.21 58:Grounded13.3.22 59:TempDev. i2tResolution Level Response Fault counterUnbalan

Pagina 105

DiagnosisOperating Manual92ID 442281.00WE KEEP THINGS MOVING1313.3.23 60-67:Application events 0-713.3.24 68: External faultResolution Level Response

Pagina 106

DiagnosisOperating Manual93ID 442281.00WE KEEP THINGS MOVING1313.3.25 69:Motor connect.Resolution Level Response Fault counterMotor connection error C

Pagina 107

DiagnosisOperating Manual94ID 442281.00WE KEEP THINGS MOVING1313.3.26 70:Param.consistResolution Level Response Fault counterConflicting parameterizat

Pagina 108

DiagnosisOperating Manual95ID 442281.00WE KEEP THINGS MOVING136:Torque limit When using the values entered in C03 or C05, the maximum current of the i

Pagina 109

DiagnosisOperating Manual96ID 442281.00WE KEEP THINGS MOVING1313.3.27 71:FirmwareResolution Level Response Fault counterA firmware error was detected.

Pagina 110

DiagnosisOperating Manual97ID 442281.00WE KEEP THINGS MOVING1313.3.28 72:Brake testResolution Level Response Fault counterFor active brake manage-ment

Pagina 111 - Global Presence

DiagnosisOperating Manual98ID 442281.00WE KEEP THINGS MOVING1313.3.29 73:Ax2braketestResolution Level Response Fault counterFor active brake manage-me

Pagina 112

DiagnosisOperating Manual99ID 442281.00WE KEEP THINGS MOVING1313.3.30 74:Ax3braketestResolution Level Response Fault counterFor active brake manage-me

Comentarios a estos manuales